  T-2000 Transformer Test Set  
   

• CT excitation, ratio and polarity test;
• Primary injection testing capabilities;
• 3000V AC Hipot Testing;
• Generation up to 800Amps;     
• Test results & setting are saved into local memory.

 
Download Brochure
Click here
       
  T-3000 CT, PT, VT & Relay Testing  
   

• Primary Injection testing capabilities;
• Generates up to 800A (Optional up to 4000A);
• 3000V AC Hipot Testing;
• Test result and settings are saved into local memory;
• Large graphical display.

 
Download Brochure
Click here
       
  HC5 Mobile High Current Test Set  
   

• Ruggedly constructed for field use;
• High current output with appropriate controls & instrumentation;
• Output up to 1000A, 5V;
• Overload: 5000Amps;
• Short duration overloads are possible on each taps

 
Download Brochure
Click here
       
  EZCT, Current-Transformer Test Set (2 Amperes)  
    • Portable current-transformer test set
• 16.8”W x 12.6”H x 12”D (42.7 cm x 32 cm x 26.9 cm); Weight: 55 lbs (25 Kg)
• 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
• ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1
• 0 – 50 Vac @ 2A max; 0 – 200 Vac @ 2A max; 0 – 1200 Vac @ 1.5A max (5 min on, 10 min off)
• 0 – 1,250 Vac; Accuracy: ±1.0% of reading, ±0.5 volt
• 0 – 10A; Accuracy: ±1.0% of reading, ±0.01A
• 0.8 – 99: ±0.5%, 100 – 999: ±1.0%, 1,000 – 5,000: ±2%
• 0 – 360 degrees; Accuracy: ±1.0 degree
• Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
• Built-in 4.5-inch wide thermal printer
• One RS-232C port, One USB port
• Windows® XP/Vista-based software is included with purchase price
• Stores 128 test records. Each test record may contain up to 10 excitation and ratio data sets
• Stores 10 test header records
• Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
• Operating: -10° to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
• One 20-foot X cable set, One 35-foot H cable set, power cord, One cable carrying duffel bag
• Transportation case
• One year on parts and labor

 
Download Brochure
Click here
       
  EZCT-10, Current-Transformer Test Set (10 Amperes)  
    • Portable current-transformer test set
• 16.8”W x 12.6”H x 12”D (42.7 cm x 32 cm x 26.9 cm); Weight: 55 lbs (25 Kg)
• 100 – 120 Vac or 200 - 240 Vac (factory pre-set), 50/60 Hz
• ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1
• 0 – 50 Vac @ 10A max; 0 – 200 Vac @ 10A max; 0 – 1200 Vac @ 1.5A max (5 min on, 10 min   off)
• 0 – 1,250 Vac; Accuracy: ±1.0% of reading, ±0.5 volt
• 0 – 10A; Accuracy: ±1.0% of reading, ±0.02A
• 0.8 – 99: ±0.5%, 100 – 999: ±1.0%, 1,000 – 5,000: ±2%
• 0 – 360 degrees; Accuracy: ±1.0 degree
• Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
• Built-in 4.5-inch wide thermal printer
• One RS-232C port, One USB port
• Windows® XP/Vista-based software is included with purchase price
• Stores 128 test records. Each test record may contain up to 10 excitation and ratio data sets
• Stores 10 test header records
• Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
• Operating: -10° to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
• One 20-foot X cable set, One 35-foot H cable set, power cord, One cable carrying duffel bag
• Transportation case
• One year on parts and labor

 
Download Brochure
Click here
       
 
  EZCT S2, Current-Transformer Test Set (1,500VAC)  
    • Portable current transformer test set
• 16.8”W x 12.6”H x 12”D (42.7 cm x 32 cm x 26.9 cm); Weight: 48 lbs (21 kg)
• 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50 Hz/60 Hz
• ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1
• 0 – 50 Vac @ 10A max, 0 – 250 Vac @ 10A max
• 0 – 500 Vac @ 5A max, 0 – 1500 Vac @ 1.2A max
• 0 – 2,200 Vac; Accuracy: ±1.0% of reading, ±1 volt
• 0 – 10A; Accuracy: ±1.0% of reading, ±0.02A
• 0.8 – 999: 0.1%, 1000 – 1999: 0.3%, 2000 – 5000: 1%
• 0 - 360 degrees; Accuracy: ±1.0 degree
• Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
• Built-in 4.5-inch wide thermal printer
• One RS-232C port (115k baud), one USB port
• Windows® XP/Vista-based CT Analysis software is included with purchase price
• Stores 140 test records. Each test record may contain up to 10 sets of excitation, resistance and    ratio data
• Stores 128 test plans. Each test plan can store 10 excitation test voltage and current settings
• Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
• Operating: -10° to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
• Two 20-foot X cable sets, One 35-foot H cable set, power cord, One cable-carrying duffel bag
• One year on parts and labor

 
Download Brochure
Click here
       
 
  EZCT-2000, Current-Transformer Test Set (2,000 VAC)  
    • Portable current-transformer test set
• 16.8”W x 12.6”H x 14”D (42.7 cm x 32.0 cm x 35.6 cm); Weight: 60 lbs (27.2 Kg)
• 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
• ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1
• 0 – 50 Vac @ 10A max, 0 – 300 Vac @ 10A max, 0 – 500 Vac @ 5A max
• 0 – 1200 Vac @ 2A max, 0 – 2000 Vac @ 1.2 A max
• 0 – 2,200 Vac; Accuracy: ±1.0% of reading, ±1 volt
• 0 – 10A; Accuracy: ±1.0% of reading, ±0.02A
• 0.8 – 999: 0.1%, 1000 – 1999: 0.3%, 2000 – 5000: 1%
• 0 – 360 degrees, Accuracy: ±1.0 degree
• 100 micro-ohms – 10 ohms, Accuracy: 2% of reading, ±1 count, ±10 ohms
• Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
• Built-in 4.5-inch wide thermal printer
• One RS-232C port (115k baud), One USB port
• Windows® XP/Vista-based CT Analysis software is included with purchase price
• Stores 140 test records. Each test record may contain up to 10 sets of excitation, resistance and ratio data
• Stores 128 test plans. Each test plan can store 10 excitation test voltage and current settings
• Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
• Operating: -10° to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
• Five 20-foot X cable sets, One 35-foot H cable set, power cord, One cable-carrying duffel bag
• One year on parts and labor

 
Download Brochure
Click here
       
 
 

EZCT-2000b, Current-Transformer Test Set (2,000 VAC) with Insulation and Burden Calculation  Capabilities.

 
    • Portable current-transformer test set
• 19”W X 13”H x 15.8” D (48.3 cm x 33.0 cm x 40.1 cm); Weight: 73 lbs (33.1 kg)
• 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
• ANSI/IEEE C57.12.90 and ANSI/IEEE C57.13.1 standards
• 0 – 50 Vac @ 10A max; 0 – 300 Vac @ 10A max; 0 – 500 Vac @ 5A max; 0 – 1200 Vac @ 1.2A     max; 0 – 2000 Vac @ 1A max
• 0 – 2000 Vac @ 1A max
• 1 – 20A @ 0 – 15 Vac
• Test current and current on-time
• 0 – 2,200 Vac; Accuracy: ±1.0% of reading, ±1 V
• 0 – 10A; Accuracy: ±1.0% of reading, ±0.02A
• 0.8 – 999: 0.1%; 1000 – 1999: 0.3%; 2,000 – 5,000: 1%
• 0 – 360 degrees; Accuracy: ±1.0 degree)
• 100 micro-ohms – 10 ohms; Accuracy: 2% of reading, ±1 count
• 2 Mega-ohms – 500 Mega-ohms; Accuracy: 3% of reading, 500 – 1000 Vdc test voltage
• Back-lit LCD Screen (128 x 64 dot graphic); viewable in bright sunlight and low-light levels
• Built-in 4.5-inch wide thermal printer
• One RS-232C (115,000 Baud) port, One USB port
• One USB Flash drive interface port
• Windows® XP/Vista-based CT Analysis software is included with the purchase price
• Stores 140 test records. Each test record may contain up to 10 saturation curves, current ratio   readings and polarity & DC resistance readings
• Stores 128 test plans. A test plan consists of the saturation test voltage, current selection, CT   nameplate ratios, and CT winding terminal combinations (X1 to X5) for each test
• Designed to meet UL 6110A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
• Operating: -10° to 50° C (15°F to +122° F); Storage: -30° C to 70° C (-22°F to +158° F)
• Five 20-foot X cable sets, One 35-foot H cable set, current source cables, insulation test cables, •    power cord, ground cable. A
• transportation case is included with the purchase price
• One year on parts and labor

 
Download Brochure
Click here
       
 

PCI-600, 600 Amp Primary Current Injection Source

 
    • Isolated 10 – 600 ampere AC current source
• Test protection system (using primary injection current source)
• Tests the time-delay characteristic of protection relays and
molded-case circuit-breakers
• Measures internal and external currents
• The PCI-600 is thermally protected

 
Download Brochure